Truss structure
A lightweight acrylic truss designed to fail near a 40-pound center load.
Overview
In a team of three, we designed and laser-cut an acrylic truss targeting failure near a 40-pound center load. I developed candidate geometries and calculated member forces and predicted strength-to-weight performance for my concepts. Destructive testing guided thickness revisions, and the final truss failed at the predicted member location at 38 lb, 5% below the target.


Design
Each team member developed three concepts and calculated their predicted strength-to-weight ratios. We compared each member’s strongest concept and selected the design with the highest predicted ratio. We modeled the assembly in SolidWorks, used member-force calculations to select dimensions and estimate weight, then fabricated the chosen design in acrylic.
The selected acrylic truss uses three connected triangular sections with bolted joints. The members transfer the central load to the two end supports.
Analysis & validation
We used static equilibrium to calculate member forces under the 40-pound center load, with calculated support reactions of 20 lb each. Joint equilibrium gave approximately 28.3 lb compression in the outer diagonals. Axial stress checks against an assumed 70 MPa strength guided initial dimensions and the predicted failure location.

The CAD-based weight estimate was 0.0976 lb, below the report’s fabricated weight of 0.1165 lb. We revisited stress and strength-to-weight calculations using the final thickness and recorded weight.
Fabrication & iteration
We generated DXF files from CAD, prepared them in CorelDRAW, laser-cut the acrylic members, and assembled them with screws and bolts.
We increased thickness after the first specimen failed early, then reduced it when the thicker truss exceeded the target without failure. The 3/32-inch prototype approached the target, but the final specimen failed at a lower load despite the same nominal thickness.
| Specimen | Member thickness | Observed test outcome |
|---|---|---|
| Initial | 1/16 in | Failed near 20 lb |
| Thicker | 5/32 in | Supported >50 lb without failure |
| Reduced | 3/32 in | Failed near 42 lb |
| Final | 3/32 in | Failed at 38 lb |
Results
The final truss failed at the predicted member location at 38 lb, below the 40-pound target. A change in laser cutter was identified as a possible contributor to the difference from the 42-pound prototype. Fabrication variation and modeling error were not isolated by these tests.